1,439 research outputs found

    Accuracy of Performance Measurement: An Investigation of Training Method and Amount of Practice

    Get PDF
    The purpose of this research was to investigate the effects of training method and amount of practice-and-feedback on the accuracy of performance ratings and behavioral observation. This research was a 3 x 3 factorial ANOVA design. Training method was comprised of frame-of-reference, cognitive modeling, and a no-training control group. Practice-and-feedback consisted of 0, 1, and 3 practice trials. Undergraduates (N = 99) were randomly assigned to one of nine experimental conditions. Each participant viewed and rated 7 videotaped interview simulations. The results for performance ratings indicated that (a) frame-of-reference training produced the most accurate ratings for elevation, differential elevation, and differential accuracy, and (b) practice-and-feedback did not improve accuracy. The results for behavioral observation revealed that (a) cognitive modeling training was effective in reducing the raters\u27 1-hit rates, (b) training method had no effect on false alarm rate, and (c) practice-and-feedback were ineffective for both observation error rates. Interpretation and suggestions for future research are discussed

    Measurement of {\eta} meson production in {\gamma}{\gamma} interactions and {\Gamma}({\eta}-->{\gamma}{\gamma}) with the KLOE detector

    Get PDF
    We present a measurement of {\eta} meson production in photon-photon interactions produced by electron-positron beams colliding with \sqrt{s}=1 GeV. The measurement is done with the KLOE detector at the \phi-factory DA{\Phi}NE with an integrated luminosity of 0.24 fb^{-1}. The e^+e^- --> e^+e^-{\eta} cross section is measured without detecting the outgoing electron and positron, selecting the decays {\eta}-->{\pi}^+{\pi}^-{\pi}^0 and {\eta}-->{\pi}^0{\pi}^0{\pi}^0. The most relevant background is due to e^+e^- --> {\eta}{\gamma} when the monochromatic photon escapes detection. The cross section for this process is measured as {\sigma}(e^+e^- -->{\eta}{\gamma}) = (856 \pm 8_{stat} \pm 16_{syst}) pb. The combined result for the e^+e^- -->e^+e^-{\eta} cross section is {\sigma}(e^+e^- -->e^+e^-{\eta}) = (32.72 \pm 1.27_{stat} \pm 0.70_{syst}) pb. From this we derive the partial width {\Gamma}({\eta}-->{\gamma}{\gamma}) = (520 \pm 20_{stat} \pm 13_{syst}) eV. This is in agreement with the world average and is the most precise measurement to date.Comment: Version accepted by JHE

    A new limit on the CP violating decay KS -> 3pi0 with the KLOE experiment

    Full text link
    We have carried out a new direct search for the CP violating decay KS -> 3pi0 with 1.7 fb^-1 of e+e- collisions collected by the KLOE detector at the phi-factory DAFNE. We have searched for this decay in a sample of about 5.9 x 10^8 KS KL events tagging the KS by means of the KL interaction in the calorimeter and requiring six prompt photons. With respect to our previous search, the analysis has been improved by increasing of a factor four the tagged sample and by a more effective background rejection of fake KS tags and spurious clusters. We find no candidates in data and simulated background samples, while we expect 0.12 standard model events. Normalizing to the number of KS -> 2pi0 events in the same sample, we set the upper limit on BR(KS -> 3pi0 < 2.6 x 10^-8 at 90% C.L., five times lower than the previous limit. We also set the upper limit on the eta_000 parameter, |eta_000 | < 0.0088 at 90% C.L., improving by a factor two the latest direct measurement.Comment: Accepted for publication in Physics Letters B (15 pages, 13 figures

    Measurement of \Gamma(\eta -> \pi^+\pi^-\gamma)/\Gamma(\eta -> \pi^+\pi^-\pi^0) with the KLOE Detector

    Full text link
    The ratio R_{\eta}=\Gamma(\eta -> \pi^+\pi^-\gamma)/\Gamma(\eta -> \pi^+\pi^-\pi^0) has been measured by analyzing 22 million \phi \to \eta \gamma decays collected by the KLOE experiment at DA\PhiNE, corresponding to an integrated luminosity of 558 pb^{-1}. The \eta \to \pi^+\pi^-\gamma proceeds both via the \rho resonant contribution, and possibly a non-resonant direct term, connected to the box anomaly. Our result, R_{\eta}= 0.1856\pm 0.0005_{stat} \pm 0.0028_{syst}, points out a sizable contribution of the direct term to the total width. The di-pion invariant mass for the \eta -> \pi^+\pi^-\gamma decay could be described in a model-independent approach in terms of a single free parameter, \alpha. The determined value of the parameter \alpha is \alpha = (1.32 \pm 0.08_{stat} +0.10/-0.09_{syst}\pm 0.02_{theo}) GeV^{-2}Comment: Paper in press, accepted by PL

    KLOE results in kaon physics and prospects for KLOE-2

    Full text link
    The phi-factory DAPHNE offers a possibility to select pure kaon beams, charged and neutral ones. In particular, neutral kaons from phi->KS KL are produced in pairs and the detection of a KS (KL) tags the presence of a KL (KS). This allows to perform precise measurements of kaon properties by means of KLOE detector. Another advantage of a phi-factory consists in fact that the neutral kaon pairs are produced in a pure quantum state (J^(PC) = 1^(--)), which allowsto investigate CP and CPT symmetries via quantum interference effects, as well as the basic principles of quantum mechanics.A review of the most recent results of the KLOE experiment at DAPHNE using pure kaon beams or via quantum interferometry is presented together with prospects for kaon physics at KLOE-2.Comment: 5 pages, 4 figures, From Phi To Psi 2011 conference, to be published in Nuclear Physics B (Proceedings Supplements

    The importance of myo-inositol and D-chiro-inositol to support fertility and reproduction

    Get PDF
    This review details the physiologic roles of two insulin sensitizers, myo-inositol (MI) and D-chiro-inositol (DCI). In the human ovary, MI is a second messenger of follicle stimulating hormone (FSH) and DCI is an aromatase inhibitor. These activities allow a treatment for polycystic ovary syndrome (PCOS) to be defined based on the combined administration of MI and DCI, where the best MI:DCI ratio is 40:1. In addition, MI plays a pivotal role in the physiology of reproduction, and has beneficial effects on the development of oocytes, spermatozoa, and embryos. By contrast, DCI has little effect on spermatozoa, but high concentrations in the ovary can negatively affect the quality of oocytes and the blastocyst. Overall, the evidence in the literature supports the beneficial effects of MI in both female and male reproduction, warranting clinical use of MI in assisted reproductive treatment (ART).Cette revue détaille les rôles physiologiques de deux sensibilisateurs à l'insuline, le myo-inositol (MI) et le D-chiro-inositol (DCI). Dans l'ovaire humain, le MI est un second messager de l'hormone folliculostimulante (FSH) et le DCI est un inhibiteur de l'aromatase. Ces activités permettent de définir un traitement du syndrome des ovaires polykystiques (SOPK) basé sur l'administration combinée de MI et de DCI, où le meilleur rapport MI:DCI est de 40:1. En outre, le MI joue un rôle essentiel dans la physiologie de la reproduction et a des effets bénéfiques sur le développement des ovocytes, des spermatozoïdes et des embryons. En revanche, le DCI a peu d'effet sur les spermatozoïdes, mais des concentrations élevées dans l'ovaire peuvent avoir un effet négatif sur la qualité des ovocytes et du blastocyste. Dans l'ensemble, les données de la littérature confirment les effets bénéfiques du MI dans la reproduction féminine et masculine, ce qui justifie l'utilisation clinique du MI dans l'assistance médicale à la procréation

    Performance Assessment in Fingerprinting and Multi Component Quantitative NMR Analyses

    Get PDF
    An interlaboratory comparison (ILC) was organized with the aim to set up quality control indicators suitable for multicomponent quantitative analysis by nuclear magnetic resonance (NMR) spectroscopy. A total of 36 NMR data sets (corresponding to 1260 NMR spectra) were produced by 30 participants using 34 NMR spectrometers. The calibration line method was chosen for the quantification of a five-component model mixture. Results show that quantitative NMR is a robust quantification tool and that 26 out of 36 data sets resulted in statistically equivalent calibration lines for all considered NMR signals. The performance of each laboratory was assessed by means of a new performance index (named Qp-score) which is related to the difference between the experimental and the consensus values of the slope of the calibration lines. Laboratories endowed with a Qp-score falling within the suitable acceptability range are qualified to produce NMR spectra that can be considered statistically equivalent in terms of relative intensities of the signals. In addition, the specific response of nuclei to the experimental excitation/relaxation conditions was addressed by means of the parameter named NR. NR is related to the difference between the theoretical and the consensus slopes of the calibration lines and is specific for each signal produced by a well-defined set of acquisition parameters

    The NAMPT inhibitor FK866 reverts the damage in spinal cord injury

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Emerging data implicate nicotinamide phosphoribosyl transferase (NAMPT) in the pathogenesis of cancer and inflammation. NAMPT inhibitors have proven beneficial in inflammatory animal models of arthritis and endotoxic shock as well as in autoimmune encephalitis. Given the role of inflammatory responses in spinal cord injury (SCI), the effect of NAMPT inhibitors was examined in this setting.</p> <p>Methods</p> <p>We investigated the effects of the NAMPT inhibitor FK866 in an experimental compression model of SCI.</p> <p>Results</p> <p>Twenty-four hr following induction of SCI, a significant functional deficit accompanied widespread edema, demyelination, neuron loss and a substantial increase in TNF-α, IL-1β, PAR, NAMPT, Bax, MPO activity, NF-κB activation, astrogliosis and microglial activation was observed. Meanwhile, the expression of neurotrophins BDNF, GDNF, NT3 and anti-apoptotic Bcl-2 decreased significantly. Treatment with FK866 (10 mg/kg), the best known and characterized NAMPT inhibitor, at 1 h and 6 h after SCI rescued motor function, preserved perilesional gray and white matter, restored anti-apoptotic and neurotrophic factors, prevented the activation of neutrophils, microglia and astrocytes and inhibited the elevation of NAMPT, PAR, TNF-α, IL-1β, Bax expression and NF-κB activity.</p> <p>We show for the first time that FK866, a specific inhibitor of NAMPT, administered after SCI, is capable of reducing the secondary inflammatory injury and partly reduce permanent damage. We also show that NAMPT protein levels are increased upon SCI in the perilesional area which can be corrected by administration of FK866.</p> <p>Conclusions</p> <p>Our findings suggest that the inflammatory component associated to SCI is the primary target of these inhibitors.</p

    Measurement of the correlation between the polar angles of leptons from top quark decays in the helicity basis at √s = 7 TeV using the ATLAS detector

    Get PDF
    A measurement of the correlations between the polar angles of leptons from the decay of pair-produced t and t̄ quarks in the helicity basis is reported, using proton-proton collision data collected by the ATLAS detector at the LHC. The dataset corresponds to an integrated luminosity of 4.6  fb−¹ at a center-of-mass energy of √s = 7  TeV collected during 2011. Candidate events are selected in the dilepton topology with large missing transverse momentum and at least two jets. The angles θ1 and θ2 between the charged leptons and the direction of motion of the parent quarks in the tt̄ rest frame are sensitive to the spin information, and the distribution of cosθ1 ⋅ cosθ2 is sensitive to the spin correlation between the t and t̄ quarks. The distribution is unfolded to parton level and compared to the next-to-leading order prediction. A good agreement is observed
    corecore